Specifications
Camera interfaces
Bonito Technical Manual V2.2.1
25
Trigger input (pin 10-11)
The current through the optocoupler’s LED should be in the range of 5 mA to
15 mA. This is the case if 5.0 V ≤ V
in
≤ 12 V.
A rising edge at this optocoupler input starts the exposure. It depends on the
trigger input selection T and the current trigger mode M whether this input is
enabled and how it controls the exposure time.
The optocoupler adds a typical delay of about 0.1 s to the externally applied
signal.
For more information on the various trigger and exposure modes: see Chapter
Exposure control mode (M) on page 40.
Exposure output (pin 12-13)
Figure 13: Trigger input diagram
Note
If you use higher voltages, you have to connect externally an
additional current limiting resistor.
Figure 14: Exposure output