Specifications

Parameters and Commands
Bonito Technical Manual V2.2.1
35
Parameters and Commands
This section explains the basic Bonito configuration parameters and general
commands available to the user. Parameters and commands are communicated
using the camera’s serial interface.
Primary starting address (A)
The parameter A defines which line of the image sensor is the first line of the
output image. The sensor’s first (topmost) line has the address A=0, the last
line has the address A=6BD. The value of A in conjunction with N and I is
used to create a region of interest (ROI1). By default it is set to A=0.
Following sketch illustrates the various ROI parameters from the sensor’s point
of view:
Note
For more information see Chapter Serial I/O on page 20.
Figure 22: ROI parameters