Exposure control mode (M)
There are various modes available to control the exposure time and frame dura-
tion of the Bonito CL-400B/C. The exposure control is depending on some gen-
eral timing parameters which are specified in the following table:
Use parameter M to setup the exposure control mode. The bits of the parame-
ter value are divided into three different sized bit groups e, p and f. Each bit
group has a special function being independent of the other ones:
Parameter Value
Line Duration (S=0) t
L
= 3 s
Line Duration (S=1) t
L
= 1.5 s
Line Duration (S=3) t
L
= 1.5 s
Frame Output Time (D=0) t
F
= (N + 1) * t
L
Frame Output Time (D=1) t
F
= 2 * (N + 1) * t
L
Minimum Frame Duration t
FDmin
= t
F
+ t
L
Timer Resolution t
TR
= (K + 1) / 56 MHz
Table 7: Exposure control parameters
Bit group Description
e Exposure timing mode
p PIV mode
f Exposure feature mode
Table 8: Exposure control mode: bit groups
7654 3210
--ff -pee
rw rw rw rw rw
Table 9: Exposure control mode: bit field order