Specifications
Parameters and Commands
Bonito Technical Manual V2.2.1
45
Bit group Value Function
f0Standard mode
f1Enhanced full well (3T) mode
The full frame shutter is not available in this mode. Instead, the sensor oper-
ates in rolling shutter mode with an effective shutter time equaling the frame
duration. Thus a synchronized strobe light is recommended.
Consequently any exposure time setting, controlled by Parameter E or by
external signal, is ignored.
The light should flash between two image readout operations, which may be
the duration of one line at highest possible frame rate.
Decrease the frame rate accordingly, if longer exposure times are needed. Use
the sync output (RS232 driver at pin 6) for synchronization, if needed.
f2Permanent exposure mode
Use this mode to maximize the exposure time.
If activated, the exposure time equals the frame duration.
Consequently any exposure time setting, controlled by parameter E or by
external signal, is ignored.
f3Reserved
Table 15: Exposure control modes: Exposure timing mode (bit group: f)