Technical information
AVT GigE camera attributes
AVT GigE Camera and Driver Attributes V1.3.1
22
This document is a master document for all AVT GigE camera models and is NOT camera specific
EFLensStatus
EFLensID – Integer – R
Identification value of the attached EF lens.
EFLensLastError – Enum – R
Most recently detected error.
EFLensState – Enum – R
Current EF lens state.
EFLensInitialize – Command
Initializes the EF lens. This command is automatically executed on power up
and/or when lens is attached to camera.
EFLensZoom
EFLensZoomCurrent – Integer – R
Current focal length of the EF lens.
EFLensZoomMax – Integer – R
Maximum focal length of the EF lens.
EFLensZoomMin – Integer – R
Minimum focal length of the EF lens.
EFLensErrNone No error detected
EFLensErrQuery Lens failed query by camera
EFLensErrInternal1 Lens communication error (can occur when removing
lens)
EFLensErrInternal2 Lens communication error (can occur when removing
lens)
EFLensErrBusy Lens remained busy for longer than 10 seconds
EFLensErrZeroStop Lens focus “Zero Stop” not detected
EFLensErrInfinityStop Lens focus “Infinity Stop” not detected
EFLensIdle No lens action in progress
EFLensBusy Lens is busy (changing focus or aperture)
EFLensWaiting Camera is waiting for lens attachment
EFLensInitializing Camera is initializing lens
EFLensError Lens Error detected. Error type is indicated by
EFLensLastError. Remains in this state until
EFLensInitialize is executed
Range: [EFLensZoomMin – EFLensZoomMax]
Units: mm
Default: Lens dependent Units: mm
Default: Lens dependent Units: mm