Technical information

AVT GigE camera attributes
AVT GigE Camera and Driver Attributes V1.3.1
31
This document is a master document for all AVT GigE camera models and is NOT camera specific
IrisVideoLevelMax – Uint32 – R/W
Video-type lenses only. Limits the maximum driving voltage for closing the lens
iris.
IrisVideoLevelMin – Uint32 – R/W
Video-type lenses only. Limits the minimum driving voltage for opening the
lens iris.
LensDCIris
DC Iris lenses only.
LensDCDriveStrength – Uint32 – R/W
Lens drive voltage. Altering this changes the speed at which a DC-Iris lens oper-
ates. The lower the value, the slower the lens operates. A higher value may
result in iris oscillation. The optimum value is lens dependent. Larger lenses
typically require a larger drive voltage.
LensPIris
P-Iris lenses only. P-Iris allows discrete iris positions using an internal lens
stepping motor.
LensPIrisFrequency – Uint32 – R/W
Stepping motor drive rate. Lens dependent. Use value defined in application
note on supported P-iris lenses or contact lens manufacturer.
LensPIrisNumSteps – Uint32 – R/W
Maximum number of discrete iris/aperture positions. Use value defined in
application note on supported P-iris lenses, or contact lens manufacturer.
LensPIrisPosition – Uint32 – R/W
Iris/aperture position. Manually control iris in PIrisManual mode, or read iris
position in PIrisAuto mode. 0 = fully open, LensPIrisNumSteps = fully closed.
Values greater than LensPIrisNumSteps are ignored/not written.
Range: [0 – 150] Default: Camera dependent Units: 10 mV [Manta: 13.2 mV]
Range: [0 – 150] Default: Camera dependent Units: 10 mV [Manta: 13.2 mV]
Range: [0 – 50] Default: 10
www
For a list of P-Iris supported lenses, along with their
LensPIrisFrequency and LensPIrisNumSteps specifications:
http://www.alliedvision.com/fileadmin/content/documents/
products/cameras/various/appnote/P-
iris_Lenses_Supported_by_Prosilica_GT_Cameras.pdf
Range: [0 – 1000] Default: 100 Units: Hz
Range: [1 – 1023] Default: 50
Range: [0 – 1022] Default: 50