Technical information
AVT GigE camera attributes
AVT GigE Camera and Driver Attributes V1.3.1
51
This document is a master document for all AVT GigE camera models and is NOT camera specific
Strobe
1
Strobe is an internal signal generator for on-camera clocking functions.
Valid when any of the SyncOut modes are set to Strobe1. Strobe allows the added
functionality of duration and delay, useful when trying to sync a camera expo-
sure to an external strobe.
Strobe1ControlledDuration – Enum – R/W
When enabled, the Strobe1Duration control is valid.
Strobe1Delay – Uint32 – R/W
Delay of start of strobe signal.
Strobe1Duration – Uint32 – R/W
Duration of strobe signal.
Strobe1Mode – Enum – R/W
Associates the start of strobe signal with one of the following image capture
signals:
Possible values: On, Off Default: Off
Range: [0 - Camera dependent] Default: 0 Units: μs
Range: [0 - Camera dependent] Default: 0 Units: μs
AcquisitionTriggerReady Active once the camera has been recognized by the
host PC and is ready to start acquisition
FrameTriggerReady Active when the camera is in a state that will accept
the next frame trigger
FrameTrigger [Default] Active when an image has been initiated
to start. This is a logic trigger internal to the cam-
era, which is initiated by an external trigger or soft-
ware trigger event
Exposing Active for the duration of sensor exposure
FrameReadout Active at during frame readout, i.e. the transferring
of image data from the CCD to camera memory
Imaging Active during exposure and readout
Acquiring Active during an acquisition stream
SyncIn1 Active when there is an external trigger at SyncIn1
SyncIn2 Active when there is an external trigger at SyncIn2
SyncIn3 Active when there is an external trigger at SyncIn3
SyncIn4 Active when there is an external trigger at SyncIn4
Note
For detailed information see the camera waveform
diagrams provided in the camera manuals.