Specifications

Data interface
Goldeye Technical Manual V2.4.0
45
The camera can be single triggered or periodically triggered with a fixed frame
rate (t
p
) up to the maximum frame rate of 118 fps (Goldeye xy-008) or 30 fps
(Goldeye xy-032).
Figure 15: Trigger input diagram
Goldeye xy-008 Goldeye xy-032
t
P
: Trigger period
t
EXP
: Exposure time
t
R
: Readout time
t
R
= 8.2 ms (320 x 256)
t
R
= 5.1 ms (320 x 160)
t
F
: Frame period (t
F
= t
P
)
t
Fc
: Frame period in continuous mode
t
Fc
= 8.45 ms (320 x 256)
t
Fc
= 5.38 ms (320 x 160)
t
P
t
Fc
t
P
– t
EXP
> 64 μs (Must be kept!)
t
P
: Trigger period
t
EXP
: Exposure time
t
R
: Readout time
t
R
= 32.4 ms
t
F
: Frame period (t
F
= t
P
)
t
Fc
: Frame period in continuous mode
t
Fc
= 33.0 ms
t
P
t
Fc
t
P
– t
EXP
> 574 μs (Must be kept!)
Table 20: Trigger input values
Model Goldeye xy-008 Goldeye xy-032
Max exposure delay t
EXP
< t
P
- t
R
– 192 μs: max. 5 μs
else: max. 1 line
(also for reduced resolution)
max. 5 μs
Max jitter t
EXP
< t
P
- t
R
– 192 μs: max. 1 pixel
else: max. 1 line
max. 1 pixel
Table 21: Exposure delay and jitter