Specifications
>k=0[CR]
S=0A
>
Goldeye xy-008 If k is not set to 0 the automatic search starts at approx. each k * 256
images. At a frame rate of e.g. 50 images per second the chronological resolu-
tion of the k value is approx. 5.1 seconds.
Goldeye xy-032 If k is not set to 0 the automatic search starts at approx. each k * 256
images. At a frame rate of e.g. 30 images per second the chronological resolu-
tion of the k value is approx. 8.53 seconds.
Example
Goldeye xy-008 The automatic correction data selection shall always be started approx. every
1200 seconds (20 minutes): 1200 s / 5.1 s per count ≈ 235 = 0xEB.
Goldeye xy-032 The automatic correction data selection shall always be started approx. every
1200 seconds (20 minutes): 1200 s / 8.53 s per count ≈ 140 = 0x8C.
>k=EB [CR](example Goldeye xy-008)
S=0A(...at once)
>S=0B(...after each 235 * 256 images...)
(...)
Select a correction data set (S)
All Goldeye xy-... cameras are equipped with multiple correction data sets for
different operation conditions. The image quality can be improved by activating
another correction data set if the environmental conditions have changed.
For a quick access to the different correction data sets, the correction data
memory is subdivided into 32 single pages. Each of these pages can store a com-
plete set of correction data (parameters A and B). At all times only one page
can be active simultaneously and all eventual modification of the correction
data takes place within this page. For each correction memory page a further
pair of registers for the parameters J and K is available. To enable an access
on the values J and K of each correction data set, the page address also
serves as access address to the register pairs.
GigE feature name (CameraSpecialFeatures) Feature Visibility Description
AutoCalibrateOnce Beginner Start the automatic calibration
once.
(k=0 command)
The processing of this com-
mand can take several seconds,
depending on the current
frame rate and the number of
correction data sets available.
Table 28: GigE feature: AutoCalibrateOnce