Specifications
Appendix
Goldeye Technical Manual V2.4.0
81
 represented in 16 bits fixed point two's complement notation.
 See parameter m=<p8> for more details about drift 
 compensation. Changing this parameter may void ex factory 
 calibration.
p=<p16> : (IRC-320/600, Pearleye P-007/030 only:)
 User specified parameter for the 
 temperature drift compensation. This is a value represented 
 in 16 bits fixed point two's complement notation. The value 
 is an additional offset value to fine adjust the camera. See 
 parameter m=<p8> for more details about drift compensation.
q=<p8> : (IRC-320/600, Pearleye P-007/030 only:)
 File number of the binary table data for 
 the temperature dependant mean value correction (see 
 parameter j=<p16>). The file consists of sampling points 
 given as binary value pairs (temperature, M). The correction
 interpolates linearly between two sampling points and
 extrapolates beyond the edges of the covered temperature
 range. Correction data is recorded during the factory
 calibration process. Changing this parameter or the specified
 file contents may void ex factory calibration.
s=<p8> : Configure the UART(s) for main serial communications. Changes
 are activated immediately.
 <eaa*_bbbb>
 |\| \__|
 | | +---b: Baud rate of the main UART and (if
 | | availiable) the second channel UART. The
 | | second channel UART supports 9600 to 115200
 | | Baud only.
 | | 0 -> 110 Baud.
 | | 1 -> 300 Baud.
 | | 2 -> 600 Baud.
 | | 3 -> 1200 Baud.
 | | 4 -> 2400 Baud.
 | | 5 -> 4800 Baud.
 | | 6 -> 9600 Baud.
 | | 7 -> 19200 Baud.
 | | 8 -> 38400 Baud.
 | | 9 -> 57600 Baud.
 | | A -> 115200 Baud.
 | +---------a: Second channel UART configuration. This
 | channel is equivalent to the main UART
 | concerning the use as command interface.
 | But it is not intended to use both UARTs at
 | the same time, because they share the same
 | receive buffer. Output characters are always
 | sent to both channels.
 | 00 -> Second channel UART off. The active
 |  serial communication port is selected
 |  by hardware jumper settings.
 | 01 -> Activate second channel via the frame
 |  grabber's serial port. This is either
 |  Camera Link TG/TC or Pleora device
 |  port serial 0.
 | 10 -> Activate second channel via Pleora
 |  device port bulk 0 (MODE:UART,