Technical information
GigE camera and driver features
GigE Camera and Drivers Features V3.0.0
18
This document is a master document for all Allied Vision GigE camera models and is NOT camera specific
TriggerDelayAbs [Float] R/W
Start-of-image can be delayed to begin some time after a trigger event is
received by the camera. This feature is valid only when TriggerSource is
set to external trigger (i.e. Line1, Line2). This control is a common trigger
to sync with a strobe lighting source, which will inherently have some fixed
setup time.
TriggerMode [Enum] R/W
Enables or disables trigger set in TriggerSelector.
TriggerOverlap [Enum] R/W
Permitted window of trigger activation, relative to previous frame. Does not
work with Software triggering. Only external.
TriggerSelector [Enum] R/W
Selects a trigger, then use the controls {TriggerMode, TriggerSoft-
ware, TriggerSource, TriggerActivation, TriggerOverlap,
TriggerDelayAbs} to setup and read the trigger features.
TriggerSoftware [Command]
Triggers an image. Valid when TriggerSource = Software.
TriggerSource [Enum] R/W
Determines how an image frame is initiated within an acquisition stream.
Range:[0 – Camera dependent] Default: 0 Unit: µs
Off Trigger disabled
On [Default] Trigger enabled
Note
If TriggerMode = Off and TriggerSelector =
FrameStart, images triggered in FixedRate at
AcquisitionFrameRateAbs.
Off [Default] Any external trigger received before a high
FrameTriggerReady signal is ignored
PreviousFrame Any external trigger received before FrameTrigger-
Ready is latched and used to trigger the next frame
FrameStart [Default] The trigger which starts each image
(when acquisition is running)
AcquisitionStart The trigger which starts the acquisition process
AcquisitionEnd The trigger which ends the acquisition process
AcquisitionRecord