Technical information
GigE camera and driver features
GigE Camera and Drivers Features V3.0.0
19
This document is a master document for all Allied Vision GigE camera models and is NOT camera specific
BufferHandlingControl
StreamAnnounceBufferMinimum [Integer] R
For Vimba v1.3 or higher only Minimal number of buffers to announce to enable selected acquisition mode.
StreamAnnouncedBufferCount [Integer] R
For Vimba v1.3 or higher only Number of announced (known) buffers on this stream.
StreamBufferHandlingMode [Enum] R/W
For Vimba v1.3 or higher only Available buffer handling modes of this stream.
Controls
BlackLevelControl
BlackLevel [Float] R/W
Black level value. Setting the Gain does not change the BlackLevel.
BlackLevelSelector [Enum] R/W
CCDTemperatureOK [Integer] R
Current temperature status of the CCD sensor. Momentary temperature status of
the CCD sensor. Indicates if CCD sensor has desired cooling temperature.
Note
An acquisition stream must be started in order to
trigger/receive individual frames. For Freerun
and FixedRate the first frame is synchronized
to AcquisitionStart trigger.
Freerun [Default] Camera runs at maximum supported frame rate
depending on the exposure time and region of interest size
Line1 External trigger Line1
Line2 External trigger Line2
Line3 External trigger Line3
Line4 External trigger Line4
FixedRate Camera self-triggers at a fixed frame rate defined by
AcquisitionFrameRateAbs
Software Software initiated image capture
Display name: Stream Announce Buffer Minimum
Display name: Stream Announced Buffer Count
Display name: Stream Buffer Handling Mode
Range: [0–255.75] Default: 0
All [Default] BlackLevel will be applied to all channels or taps