Technical information
GigE camera and driver features
GigE Camera and Drivers Features V3.0.0
29
This document is a master document for all Allied Vision GigE camera models and is NOT camera specific
Hue [Float] R/W
Alters color of image without altering white balance. Takes float input,
although rounds to integer. Only valid when using on-camera interpolated
PixelFormats .
IODMode [Enum] R/W
Set camera to continuous or Image on Demand (IOD) mode.
Iris
Auto iris lens support. Supported auto iris lens types (camera dependent):
video, DC, and P-Iris. GT series detects lens type on power up. DC settings will
not apply if P-Iris lens connected. P-Iris settings will not apply if DC-Iris lens
connected.
The auto iris algorithm calculates IrisAutoTarget based on information of
the current image, and applies this to the next image. Large changes in scene
lighting may require 2-3 frames for the algorithm to stabilize. Adding simulta-
Range: Camera dependent Default: 0.00 Unit: Degrees
Continuous
• The camera requires no external exposure signal
• The camera generates a constant exposure time inde-
pendently. The exposure time is equal to frame readout
time and cannot be adjusted
Bigeye G-132B Cool, Bigeye G-283B Cool, and Bigeye G-
1100B Cool achieve maximum frame rate in continuous
mode only.
IOD [Default] Enables IOD mode. In this mode the camera needs
an external trigger signal or a timer driven internal expo-
sure signal
LineIn1 The camera is switched between IOD and Continuous
mode, dependent on the level of LineIn1
LineIn2 The camera is switched between IOD and Continuous
mode, dependent on the level of LineIn2
LineIn3 The camera is switched between IOD and Continuous
mode, dependent on the level of LineIn3
LineIn4 The camera is switched between IOD and Continuous
mode, dependent on the level of LineIn4
LineIn5 The camera is switched between IOD and Continuous
mode, dependent on the level of LineIn5
Note
If Continuous mode is activated, no external expo-
sure signal is allowed. Set e.g. TriggerSelector
to FrameStart and TriggerSource to an
unused external trigger Line.