Technical information

GigE camera and driver features
GigE Camera and Drivers Features V3.0.0
32
This document is a master document for all Allied Vision GigE camera models and is NOT camera specific
LensDriveCommand [Enum] R/W
Setting to any non-Stop value will execute the function for LensDriveDur-
ation and then return to Stop.
LensDriveDuration [Integer] R/W
Duration of timed lens commands.
LensVoltage [Integer] R
Reports the lens power supply voltage.
LensVoltageControl [Integer] R/W
Lens power supply voltage control. See lens documentation for appropriate
voltage level. Set desired lens voltage in mV*100001.This is done to prevent
users inadvertently setting an inappropriate voltage, possibly damaging the
lens. If a bad value is written this control resets to 0.
LUTControl
Use of a LUT allows any function (in the form Output = F(Input)) to be stored in
the camera's memory and to be applied on the individual pixels of an image at
runtime.
LUTEnable [Boolean] R/W
Activates or deactivates the selected LUT.
LUTIndex [Integer] R/W
Controls the index (offset) of coefficient to access in the selected LUT.
LUTInfo
This control provides active LUT information.
LUTAddress [Integer] R/C
Indicates location of memory, when LUT is loaded.
Stop No action
IrisTimedOpen Open lens iris
IrisTimedClose Close lens iris
FocusTimedNear Shorten working distance
FocusTimedFar Lengthen working distance
ZoomTimedIn Zoom in
ZoomTimedOut Zoom out
Range: [0–5000] Default: 0 Unit: ms
Range: [0–12000] Default: 0 Unit: mV
Range: [0–1200012000] Default: 0 Unit: mV * 100001
Note
Color cameras only:
LUTControl with single color panes will not work
when binning is enabled, due to loss of color
information.
Possible values: True, False Default: False
Range: [0 – (2
LUTBitDepthIn
- 1)]
Default: 0