ExposureMode [Enum] R/W
Control for exposure duration.
ExposureTime [Float] R/W
The sensor integration time.
RecorderPreEventCount [Integer] R/W
Valid when AcquisitionMode = Recorder. The number of frames
returned before the AcquisitionRecord trigger event, with Acquisi-
tionFrameCount minus RecorderPreEventCount frames being
returned after the AcquisitionRecord trigger event.
TriggerActivation [Enum] R/W
Type of activation, for hardware triggers. This controls edge/level and polarity
sensitivities.
TriggerDelay [Float] R/W
Start-of-image can be delayed to begin some time after a trigger event is
received by the camera. This feature is valid only when TriggerSource is
set to external trigger (i.e. Line1, Line2). This control is a common trigger
to sync with a strobe lighting source, which will inherently have some fixed
setup time.
TriggerMode [Enum] R/W
Enables or disables trigger set in TriggerSelector.
Timed [Default] The camera exposure time is set by ExposureTime
Range: [Camera dependent] Unit: µs
Range:[0 – 65535] Default: 0 Unit: Frames
Note
At least one image must be captured after the
AcquisitionRecord trigger event, i.e., you
cannot set RecorderPreEventCount = 1,
and AcquisitionFrameCount = 1.
RisingEdge [Default] Rising edge trigger
FallingEdge Falling edge trigger
AnyEdge Rising or falling edge
LevelHigh Active high signal
LevelLow Active low signal
Range:[0 – Camera dependent] Default: 0 Unit: µs
Off Trigger disabled
On [Default] Trigger enabled