Technical information
GigE Camera and Drivers Features V3.0.0
69
GigE IR & scientific camera and driver features
This document is a master document for all Allied Vision GigE camera models and is NOT camera specific
LineOutPolarity [Enum] R/W
Polarity applied to the LineOut specified by LineOutSelector.
LineOutSelector [Enum] R/W
Selects the LineOut to control with LineOutSource, LineOutPolar-
ity.
LineOutSource [Enum] R/W
Signal source of the LineOut line specified by LineOutSelector.
Note
LineOutPolarity can invert the LineOutLevels.
Possible values: Normal, Invert Default: Normal
Possible values: LineOut1, LineOut2, LineOut3 Default: LineOut1
GPO General purpose output
AcquisitionTriggerReady Active once the camera has been recog-
nized by the host PC and is ready to start
acquisition
FrameTriggerReady Active when the camera is in a state that
will accept the next frame trigger
Exposing [Default] Active for the duration of sen-
sor exposure
FrameReadout Active during frame readout, i.e. the
transferring of image data from the CCD
to camera memory
Imaging Active when the camera is exposing or
reading out frame data
Acquiring Active when acquisition start has been
initiated
LineIn1 Active when there is an external trigger
at Line1
LineIn2 Active when there is an external trigger
at Line2
Strobe1 The output signal is controlled accord-
ing to Strobe1 settings
Note
For detailed information see the camera waveform