Technical information
GigE Camera and Drivers Features V3.0.0
70
GigE IR & scientific camera and driver features
This document is a master document for all Allied Vision GigE camera models and is NOT camera specific
Strobe
Definition Strobe is an internal signal generator for on-camera clocking functions. Valid
when any of the LineOutSource is set to Strobe1. Strobe allows the
added functionality of duration and delay, which is useful when trying to sync a
camera exposure to an external strobe.
StrobeDelay [Integer] R/W
Delay from strobe trigger to strobe output.
StrobeDuration [Integer] R/W
Duration of strobe signal.
StrobeDurationMode [Enum] R/W
Mode of the strobe timing unit.
StrobeSource [Enum] R/W
Associates the start of strobe signal with one of the following image capture
events:
Range: [0 – Camera dependent] Default: 0 Unit: µs
Range: [0 – Camera dependent] Default: 0 Unit: µs
Source [Default] Strobe duration is the same as source duration
Controlled Strobe duration is set by StrobeDuration
AcquisitionTriggerReady Active once the camera has been recog-
nized by the host PC and is ready to start
FrameTriggerReady Active when the camera is in a state that
will accept the next frame trigger
FrameTrigger [Default] Active when an image has been
initiated to start. This is the logic trigger
signal inside of the camera. It is initiated
by an external trigger or software trigger
Exposing Active for the duration of sensor expo-
FrameReadout Active for the duration of frame readout,
i.e. the transferring of image data from
the CCD to camera memory
Acquiring Active during the acquisition stream
LineIn1 Active when there is an external trigger
LineIn2 Active when there is an external trigger
Note
For detailed information see the camera waveform
diagrams provided in the camera manuals.