Technical information

AVT GigE camera and driver features
AVT GigE Camera and Drivers Features V2.0.0
28
This document is a master document for all AVT GigE camera models and is NOT camera specific
LensPIrisPosition [Integer] R/W
Iris/aperture position. Manually control iris in PIrisManual mode, or read
back iris position in PIrisAuto mode. 0 represents fully open and 1022 rep-
resents fully closed position. Values greater than LensPIrisNumSteps are
ignored/not written.
LensDrive
Open loop DC 3 axis lens control.
LensDriveCommand [Enum] R/W
Setting to any non-Stop value will execute the function for LensDriveDur-
ation and then return to Stop.
LensDriveDuration [Integer] R/W
Duration of timed lens commands.
LensVoltage [Integer] R
Reports the lens power supply voltage.
LensVoltageControl [Integer] R/W
Lens power supply voltage control. See lens documentation for appropriate
voltage level. Set desired lens voltage in mV*100001.This is done to prevent
users inadvertently setting an inappropriate voltage, possibly damaging the
lens. If a bad value is written this control resets to 0.
LUTControl
Use of a LUT allows any function (in the form Output = F(Input)) to be stored in
the camera's memory and to be applied on the individual pixels of an image at
runtime.
LUTEnable [Boolean] R/W
Activates or deactivates the selected LUT.
Range: [0–1022] Default: 50
Stop No action
IrisTimedOpen Open lens iris
IrisTimedClose Close lens iris
FocusTimedNear Shorten working distance
FocusTimedFar Lengthen working distance
ZoomTimedIn Zoom in
ZoomTimedOut Zoom out
Range: [0–5000] Default: 0 Units: ms
Range: [0–12000] Default: 0 Units: mV
Range: [0–1200012000] Default: 0 Units: mV * 100001
Note
Color cameras only:
LUTControl with single color panes will not work
when binning is enabled, due to loss of color
information.
Possible values: True, False Default: False