Technical information

AVT GigE camera and driver features
AVT GigE Camera and Drivers Features V2.0.0
35
This document is a master document for all AVT GigE camera models and is NOT camera specific
Configuration
GevIPConfigurationMode [Enum] R/W
Current IP configuration mode.
Bits 2 – 4 (Last error): Enumerated error value:
0: No error detected
1: Lens failed query by camera
2: Lens communication error (can occur when removing lens)
3: Lens communication error (can occur when removing lens)
4: Lens remained busy for longer than 10 seconds
5: Lens focus “Zero Stop” not detected
6: Lens focus “Infinity Stop” not detected
Bits 0 – 1: Upper 2 bits of focus percentage value (see Byte 6).
[Byte 6]
These 8 bits in conjunction with bits 0 – 1 of Byte 5, indicate the current
focus position of the EF lens in (percentage of maximum focus range) * 10
(i.e. 1000 = 100 percent = Infinity Stop).
If the lens manual/auto focus switch is in the manual position these bits will
be 0.
[Byte7]
These 8 bits indicate the current aperture position of the EF lens in Dn. To
convert Dn to FStop value, use formula: FStop = 2 (Dn – 8) /16.
[Byte 8]
These 8 bits indicate the current focal length of the EF lens in mm.
[Bytes 9 – 12] Exposure value in µs.
[Bytes 13 – 16] Gain value in dB.
[Bytes 17 – 18]
Sync in levels. A bit field. Bit 0 is sync-in 0, bit 1 is sync-in 1, etc. A bit value
of 1 = level high, and a bit value of 0 = level low.
[Bytes 19 – 20]
Sync out levels. A bit field. Bit 0 is sync-out 0, bit 1 is sync-out 1, etc. A bit
value of 1 = level high, and a bit value of 0 = level low.
[Bytes 21 – 24] Reserved. 0
[Bytes 25 – 28] Reserved. 0
[Bytes 29 – 32] Reserved. 0
[Bytes 33 – 36] Reserved. 0
[Bytes 37 – 40] Reserved. 0
[Bytes 41 – 44] Chunk ID. 1000
[Bytes 45 – 48] Chunk length.
Display name: IP Configuration Mode
Possible values: LLA, DHCP, Persistent