Technical information

AVT GigE IR & scientific camera and driver features
AVT GigE Camera and Drivers Features V2.0.0
54
This document is a master document for all AVT GigE camera models and is NOT camera specific
AVT GigE IR & scientific camera and
driver features
AVT Goldeye is a short-wave infrared GigE camera that provides a comprehen-
sive and advanced set of features for infrared imaging requirements. This chap-
ter describes the standard and advanced camera controls, as seen from the AVT
Vimba Viewer, for Goldeye cameras using the GenICam standard feature nam-
ing convention.
AcquisitionControl
This group of controls relates to image acquisition.
AcquisitionAbort [Command]
Software command to stop camera from receiving frame triggers and abort the
current acquisition. A partially transferred image will be completed.
AcquisitionFrameCount [Integer] R/W
Defines the number of frames to capture in a limited sequence of images. Used
with AcquisitionMode = MultiFrame and Recorder. In Recorder
mode, AcquisitionFrameCount cannot exceed StreamHoldCapac-
ity.
AcquisitionFrameRate [Float] R/W
When TriggerSelector = FrameStart and either TriggerMode =
Off or TriggerSource = FixedRate, this control specifies the frame
rate. Depending on the exposure duration, the camera may not achieve the
frame rate set here.
AcquisitionFrameRateLimit [Float] R
The maximum frame rate possible for the current exposure duration and image
format.
Range:[1–65535] Default: 1 Units: Frames
Range: [Camera dependent] Units: Frames per second
Range: [Camera dependent] Units: Frames per second