Technical information

AVT GigE IR & scientific camera and driver features
AVT GigE Camera and Drivers Features V2.0.0
64
This document is a master document for all AVT GigE camera models and is NOT camera specific
LineOutPolarity [Enum] R/W
Polarity applied to the LineOut specified by LineOutSelector.
LineOutSelector [Enum] R/W
Selects the LineOut to control with LineOutSource, LineOutPolar-
ity.
LineOutSource [Enum] R/W
Signal source of the LineOut line specified by LineOutSelector.
Note
LineOutPolarity can invert the LineOutLevels.
Possible values: Normal, Invert Default: Normal
Possible values: LineOut1, LineOut2, LineOut3, LineOut4
Default: LineOut1
GPO General purpose output
AcquisitionTriggerReady Active once the camera has been recognized by the host PC and is
ready to start acquisition
FrameTriggerReady Active when the camera is in a state that will accept the next frame
trigger
Exposing [Default] Active for the duration of sensor exposure
FrameReadout Active during frame readout, i.e. the transferring of image data
from the CCD to camera memory
Imaging Active when the camera is exposing or reading out frame data
Acquiring Active when acquisition start has been initiated
LineIn1 Active when there is an external trigger at Line1
LineIn2 Active when there is an external trigger at Line2
LineIn3 Active when there is an external trigger at Line3
LineIn4 Active when there is an external trigger at Line4
Strobe1 The output signal is controlled according to Strobe1 settings
Note
For detailed information see the camera waveform
diagrams provided in the camera manuals.