NonUniformityCorrection
NUCDatasetActivate [Command]
Activates the data set that is currently indexed by the NUCDataSetSelec-
tor.
NUCDatasetActive [Integer] R
The index of the active data set, starting at 0. The maximum possible value
depends on the number of valid data sets in the camera. The mapping of an
index value to a specific correction data file may vary from camera to camera or
after correction data modifications. Use the NUCDatasetSelector and
corresponding features to retrieve more information about the data sets.
NUCDatasetAuto [Enum] R/W
Controls automatic selection of the NUCDatasetActive.
NUCDatasetDescription [String] R
This text corresponds to the file description in the file system of the camera.
NUCDatasetExposureTime [Float] R
Shows the exposure time at acquisition of the data set. The data set should be
selected so that the actual exposure time setting corresponds to the reference
value.
NUCDatasetGain [Float] R
SensorGain setting at acquisition of the data set. The data set should be
selected so that the actual sensor gain setting corresponds to the reference
value.
NUCDatasetNodeSelector [Integer] R/W
Selects a data point of a data set for access to its properties, starting at 0. The
maximum possible value depends on the number of valid data points in the data
set.
NUCDatasetNodeValue [Float] R
Shows the set value of the selected data point.
Range: [0 – Camera dependent]
Off [Default] The automatic mode is off
Once Auto-NUC occurs until target is achieved, then
NUCDatasetAuto returns to Off
Continuous The non-uniformity correction will continue
according to the scene illumination
0 SensorGain = LowGain
1 SensorGain = HighGain