Specifications
Pearleye P-007 LWIR / P-007 LWIR High Temp
Note
The warranty becomes void in case of unauthorized tampering
or any modifications not approved by Allied Vision Technolo-
gies.
Caution
Surge
To avoid damage caused by surge, connect the camera to an
AC/DC power supply. Use a certified industrial power supply
that complies with common industrial standards. Make sure
the polarization of the power supply is correct.
During the camera start-up, inrush currents ≥ 4 A can occur for
20 ms. Use a sufficiently dimensioned power supply to avoid
damage to the camera.
For the DC signal, use cable lengths less than 30 m. Consider
that the voltage drop increases with the cable length.
AVT (or your local dealer) provides suitable power supplies:
http://www.alliedvisiontec.com/emea/products/
accessories.html
Feature Specification
Sensor Amorphous silicon uncooled microbolometer focal plane array (FPA)
ULIS UL 03 08 1; built-in electromechanical shutter
Effective chip size 11.2 mm (H) x 8.4 mm (V)
Cell size 35 μm x 35 μm
Resolution (max.) 320 (H) x 240 (V)
Lens mount M65 x 0.5
Field of view (FOV) With 18 mm lens: 35° x 26°
Focus range 0.5 m to manually adjustable)
Spectral response 8 μm to 14 μm (LWIR)
Pixel format Mono12
Frame rate up to 40 fps
Table 3: Specification Pearleye P-007 LWIR / P-007 LWIR High Temp