Specifications

Advanced parameters and commands
Pearleye Technical Manual V2.3.0
47
Usage of the parameters is described in more detail on the following pages.
2 Deactivated
Test mode: Correction data A are output as image data. (*)
3 Deactivated
Test mode: Correction data B are output as image data. (*)
4 One-point correction: Simple subtraction of the correction data
A from the input data. In addition the set value J is added as
offset to each pixel value.
5 One point correction: Simple subtraction of the correction data
B from the input data. In addition the set value K is added as
offset to each pixel value.
Note
(*) Operating modes 2 and 3 are for test purposes.
If you activate mode 2 or 3, the module does not transmit any
incoming image data. The module outputs correction data as
image data only.
Value Description
Table 18: Parameter E: values