Instruction manual

Description of the data path
STINGRAY Technical Manual V2.2.0
135
How to transfer parameters to the camera
The following 3 variants of transferring the parameters are available:
In the following you find a short description of each variant:
Encapsulated Update (begin/end)
The Encapsulated Update (begin/end) has the following characteristics:
Host will set a parameter update begin flag in the camera (UpdActive
Field in Register 0xF1000570, see Table 140: Advanced register: Update
timing modes on page 282)
Host will send several parameters to the camera and then signalize end
by resetting the flag
All parameters will become active for the same next image
Dependent on timing mode, the camera
Figure 85: Quick Format Change Mode
Transfer mode
Advantage Disadvantage
Encapsulated Update (begin/
end)
easy to use (standard quad
writes in camera register is
possible)
one write access per register
access
Parameter-List Update only one write access for all
parameters
fastest hostcamera transfer
(from 5 parameters on faster
than encapsulated mode)
handling of parameter list
easy
not so easy to use (block
writes)
max. 64 entries for parameter
list
Standard Update (IIDC) compliant with IIDC V1.31 non deterministic change of
parameters
Table 42: Comparison of 3 transfer modes