Instruction manual

Configuration of the camera
STINGRAY Technical Manual V2.2.0
289
Advanced register: frame counter
The frame counter feature is controlled by the following advanced feature
register:
Having this feature enabled, the current frame counter value (images read
out of the sensor, equivalent to # FrameValid) will be inserted as a 32-bit
integer value into any captured image.
Setting the Reset flag to 1 resets the frame counter to 0: the Reset flag is
self-cleared.
Additionally there is a register for direct read out of the frame counter value.
Bit0123456789101112131415
Cycle offset 12 bit Cycle count ...
Bit16171819202122232425262728293031
... Cycle count 13 bit Second count 7 bit
Table 146: Cycle timer layout
Note
L
Different to Marlin SIS:
Register 610 is only to be used to reset the frame counter.
Register Name Field Bit Description
0xF1000610 FRMCNT_STAMP Presence_Inq [0] Indicates presence of this feature
(read only)
Reset [1] Reset frame counter
--- [2..31] Reserved
0xF1000614 FRMCNT [0..31] Frame counter
Table 147: Advanced register: Frame counter
Note
L
The 4 bytes of the frame counter value will be inserted as
the 5th to 8th byte of a line.