Owner's manual

Parameters and commands
Bonito Technical Manual V2.3.0
44
Related Parameters A, B, D, and N
Example I=4 output every 4
th
line
N=1AF (0x1AF = 431), sets number of lines to 431, which equals a quarter
of the full image
Synchronization output (J)
Parameter J sends an output synchronization signal to pin 6 of the camera con-
trol connector.
Valid values: Either one of the values 0, 1, 2, 3, 8, 9, A, B
Default 1
Related Parameters D, E, F, M, N and S
Setting Output signal
J=0 Effective sensor exposure
J=1
Charge transfer pulse
Active for one line duration at the end of exposure. End of this
pulse marks the end of exposure and at the same time start of sen-
sor readout.
In PIV mode: this pulse occurs at the exposure end of only the first
image of each PIV pair. For more information see chapter PIV
mode (bit group p) on page 51
J=2 Effective sensor readout
J=3
Exposure phase
Contrary to J=0, this setting shows the exposure phase of the
internal state machine and not the effective exposure of the sen-
sor. This allows to synchronize external devices even if the sensor
is in permanent exposure mode. For more details see chapter
Exposure control mode (M) on page 45.
J=8 Same as J=0, but with inverted logic on sync output
J=9 Same as J=1, but with inverted logic on sync output
J=A Same as J=2, but with inverted logic on sync output
J=B Same as J=3, but with inverted logic on sync output
Table 7: Synchronization output