Owner's manual

Parameters and commands
Bonito Technical Manual V2.3.0
46
Range From 0 to 7, from 10 to 17, from 20 to 27, from 30 to 37
Default 0
Related Parameters D, E, F, J, N, and S
Three sub-fields are available to control the exposure time and frame duration
of the Bonito CL-400B/C:
Exposure timing mode
•PIV mode
Exposure feature mode
All of these sub-fields are controlled by the parameter M, each of them working
independently from the other sub-fields. The sub-fields within the parameter M
are represented by differently sized bit groups.
To set a sub-field to a certain value, modify the associated bit group by allocat-
ing M to the appropriate hexadecimal number.
Parameter Value
Line Duration (S=0)t
L
= 3 s
Line Duration (S=1)t
L
= 1.5 s
Line Duration (S=3)t
L
= 1.5 s
Frame Output Time (D=0)t
F
= (N + 1) * t
L
Frame Output Time (D=1)t
F
= 2 * (N + 1) * t
L
Minimum Frame Duration t
FDmin
= t
F
+ t
L
Timer Resolution t
TR
= (K + 1) / 56 MHz
Table 8: Exposure control parameters
Bit group Sub-field description
e Exposure timing mode
p PIV mode
f Exposure feature mode
Table 9: Exposure control mode: attribution of bit groups and sub-fields
76543210
--ff-pee
rw rw rw rw rw
Table 10: Exposure control mode: order of bit groups within parameter M