Owner's manual
Parameters and commands
Bonito Technical Manual V2.3.0
49
The next falling edge stops the exposure and starts the output of the image syn-
chronized to the next line.
Due to the line jitter the next rising edge of the trigger should not appear earlier
than t
FDmin
+ t
L
after the previous rising edge.
Image on demand mode (IOD) with exposure timer
Bit group: e
Value: 2
The exposure time is controlled by the parameter E.
Each rising edge of an externally applied signal starts one exposure. Use param-
eter T to select the signal source.
A rising edge at the corresponding input starts exposure synchronized to the
line after the next.
The next rising edge must not arrive earlier than
t
FDmin
+ t
L
or
Figure 24: Exposure timing mode, M=1, flow diagram
Parameter Value
Trigger Period t
TP
> t
FDmin
+ t
L
Trigger High Duration t
L
< t
TH
< t
TP
– t
L
Exposure Jitter 0 < t
j
< t
L
Exposure Time t
Exp
= t
TH
– t
L
± t
j
Table 13: Exposure timing mode, M=1, timing parameters