Range From 0 to 6BD
Default 6BD
Related Parameters A, B, D, I, and M
Example 1 M=0
S=0 [t
L
= 3 ๎€ƒs]
D=0 (not for Bonito CL-400B/C 200fps cameras)
N (see table on next page)
Example 2 M=0
S=1 [t
L
= 1.5 ๎€ƒs]
D=0 (not for Bonito CL-400B/C 200fps cameras)
N (see table below)
IOD IOD=0 if Continuous mode (e.g. M=0),
IOD=1 if not in Continuous mode
t
L
t
L
= 3 ๎€ƒs in single CL channel mode (e.g. S=0),
t
L
= 1.5 ๎€ƒsin dual CL channel mode (e.g. S=1)
Setting No. of lines Minimum frame duration t
FDmin
Frame rate/fps
N=6BD 1726 5.181 ms 193.01
N=681 1666 5.001 ms 199.96
N=14B 332 0.999 ms 1001.0
N=1F 32 0.099 ms 10101
N=0 1 0.006 ms 166667
Table 20: Timing examples (M=0, S=0, D=0)
Setting No. of lines Minimum frame duration t
FDmin
Frame rate/fps
N=6BD 1726 2.5905 ms 386.03
N=681 1666 2.5005 ms 399.92
N=14B 332 0.4995 ms 2002.0
N=1F 32 0.0495 ms 20202
N=0 1 0.0030 ms 333333
Table 21: Timing examples (M=0, S=1, D=0)
Parameter Value
Table 19: Parameters for fps calculation