Owner's manual

Parameters and commands
Bonito Technical Manual V2.3.0
64
>V
Bonito CMOS High-Speed Camera
Version: CMC.040.xx.yy
>
Save parameters (X)
Use the command X=1 to store all parameter values into the embedded flash
memory. After a re-start they are automatically restored.
Parameter summary (Y)
The command Y shows a summary of all current parameter value settings.
Reset to factory defaults (Z)
The command Z=1 sets the camera into a factory default state. To save the new
parameter configuration, the command X=1 has to be executed afterwards.
The default settings are:
A=0000
B=0000
C=00
D=00
E=000006BE
F=000006BF
G=00
I=01
J=01
K=A7
M=00
N=06BD
S=00
Note
Acquired FPN correction data is not stored and is, therefore,
lost after switch-off.
See chapter Fixed pattern noise (FPN) correction (C) on page
39.