Owner's manual

Parameters and commands
Bonito Technical Manual V2.3.0
66
Serial control interface configuration (s)
Use parameter s to set up the serial control interface of the camera, such as
baud rate, enable state, or echo mode.
Range From 0 to FFFF.
Since the parameter s is divided into three different sub-fields (see further
below), the following ranges cover all possible uses of this parameter. It is rec-
ommended not to use parameters that are outside the defined ranges.
0 to A, 20 to 2A, 40 to 4A, 60 to 6A, 80 to 8A, A0 to AA, C0 to CA, E0 to EA.
Default 2A (115,200 Baud, additionally activates second channel via Camera Link con-
nector O2, each character received from the host is echoed back to it.)
Related Three sub-fields are available to control the serial control interface, of the
Bonito CL-400B/C:
Baud rate of the serial ports
Echo mode
Enable state of the serial ports
All of these sub-fields are controlled by the parameter s, however, each of them
works independently from the other sub-fields. The sub-fields are represented
by bit groups of different size within the parameter s.
4022 4064022 Bonito CL-400B EF-Mount 200fps
4030 4064030 Bonito CL-400C 200fps
4031 4064031 Bonito CL-400C F-Mount 200fps
4032 4064032 Bonito CL-400C EF-Mount 200fps
4100 4064100 Bonito CL-400BS
FFFF - Unknown / test / prototype
Bit group Sub-field description
x Controls the baud rate of the serial ports.
a Controls the enable state of the serial ports.
e Controls the echo mode.
Table 26: Attribution of bit groups and sub-fields
b Article number Camera variant
Table 25: Product variant code (b)