Owner's manual
Parameters and commands
Bonito Technical Manual V2.3.0
67
To set a sub-field to a certain value, modify the associated bit group by allocat-
ing s to the appropriate hexadecimal number.
Since all of the sub-fields are set using the parameter s, it is only possible to set
all of them at the same time. The value of s is calculated as the aggregate sum
of the hexadecimal values that are set to each of the three sub-fields.
The table below shows the hexadecimal values that can be set for each sub-
field. To work out the final value for s, select the usage for each sub-field, then
add the corresponding hexadecimal values.
FEDCBA9876543210
--------eaa-xxxx
- - - - - - - - rw rw rw rw rw rw rw
Table 27: Order of bit groups within parameter s
Bit values Settings Weight
(hexadecimal)
Baud rate of the serial ports
xxx-0000 110 Baud * 0
xxx-0001 300 Baud * 1
xxx-0010 600 Baud * 2
xxx-0011 1,200 Baud * 3
xxx-0100 2,400 Baud * 4
xxx-0101 4,800 Baud * 5
* Baud rates up to 4,800 Baud are not available via Camera Link.
xxx-0110 9,600 Baud 6
xxx-0111 19,200 Baud 7
xxx-1000 38,400 Baud 8
xxx-1001 57,600 Baud 9
xxx-1010 115,200 Baud A
Enable state of the serial ports
x00-xxxx RS232 via 15-pin D-sub connector only. 0
x01-xxxx Additionally activates second channel via
Camera Link connector O2.
20
x10-xxxx Additionally activates second channel via
Camera Link connector O4.
40
x11-xxxx
Additionally activates second channel via
Camera Link connector O2 and O4.
60
Table 28: Baud rate: hexadecimal weights for each setting