Instruction manual

Prosilica GC Technical Manual V2.1.0
69
Camera data path
Camera data path
The following diagrams illustrate the data flow and the bit resolution of image
data. The individual blocks are described in more detail in the GigE Features
Reference document.
Prosilica GC: monochrome cameras
Prosilica GC: color cameras
Figure 56: Block diagram of monochrome Prosilica GC cameras
Figure 57: Block diagram of color Prosilica GC cameras (except GC750C)
HIROSE I/O
RS232
Sensor
Analog
Analog
ADC
Analog Analog
Gain
Vertical
binning /
Vertical ROI
12* bit
12* bit
GigE
12* bit
Frame
memory
Gigabit
Ethernet
interface
Factory calibrated. NOT a user control.
Camera control
Oset
Horizontal
binning
12* bit
Horizontal
ROI
*
10 bits are used for Prosilica GC750.
HIROSE I/O
RS232
Sensor
Analog Analog
GigE
12 bit
Analog Analog
Gain
Horizontal
binning*
Vertical
binning* /
Vertical ROI
12 bit
Gigabit
Ethernet
interface
12 bit
White balance
8
bit
8/12 bit
Bayer
Interpolation
3 X 3
Frame
memory
Factory calibrated. NOT a user control.
For on-camera interpolated PixelFormats only—outputs 8 bit.
Raw un-interpolated PixelFormats skip this block—outputs 8/12 bit
depending upon the bit depth of PixelFormat used.
Oset
Analog
Camera control
Horizontal
ROI
ADC
*
Color information lost while binning is active.