Cleaning with air
Blow directly on the contaminated surface with moderate pressure, clean com-
pressed air. 
View a live image with the camera after blowing. If debris is still present, repeat 
the process until it is determined that the particulate cannot be dislodged. If 
this is the case, proceed to the contact cleaning technique.
Contact cleaning
Only use this method if the above air cleaning method does not sufficiently 
clean the surface. Use 99% pure isopropyl alcohol and clean cotton swabs. Wet 
the swab in the alcohol. Quickly wipe the optics in a single stroke. Prolonged 
exposure of alcohol on the swab can cause the swab glue to loosen and transfer 
to the optic glass. Do not reuse the same swab. Repeat this process until the 
debris is removed. If this process fails to remove the debris, contact AVT.
Note
A pin spanner wrench suitable for IR filter removal is available 
for purchase from AVT.
AVT P/N: E9020001
Caution
Do not exceed 6 bar (90 psi). If using canned air, approxi-
mately ~ 4.8 bar (70 psi) when full, do not shake or tilt the 
can, as extreme changes in temperature due to sudden cold 
air can crack the optic glass.