Instruction Manual

Goldeye Technical Manual V2.5.0
67
Example
Activate the two-point correction
>E=1[CR]
2 Deactivated
Test mode: Correction data A are output as image data. (*)
3 Deactivated
Test mode: Correction data B are output as image data. (*)
4 One-point correction:
Simple subtraction of the correction data A from the input data.
In addition, the set value J is added as offset to each pixel
value.
5 One-point correction:
Simple subtraction of the correction data B from the input
data.
In addition, the set value K is added as offset to each pixel
value.
Note
(*) Test modes 2 and 3 are for test purposes.
If you activate mode 2 or 3, the module does not transmit any
incoming image data. The module outputs correction data as
image data only.
Value Description
Table 33: Parameter E: values