Instruction Manual

Goldeye Technical Manual V2.5.0
79
a: Controls the configuration of the serial port.
e: Controls the echo mode.
x: Controls the baud rate of the serial port.
Example
Set the factory default (115200 Baud and activate serial interface via Camera
Link / Gigabit Ethernet).
>s=2A[CR]
s2A Baud rate
FEDCBA9876543210
--------eaa-xxxx
rw rw rw rw rw rw rw
Bit group Value (hex) Description
x
O110 Baud
1300 Baud
2600 Baud
3 1200 Baud
4 2400 Baud
5 4800 Baud
6 9600 Baud
7 19200 Baud
8 38400 Baud
9 57600 Baud
A 115200 Baud
a
00 RS232 via 15 pin SUB-D only
01 Frame grabber serial port (Camera Link or Pleora device port serial IO)
10 Additionally activate second channel via Pleora device port bulk 0
(MODE:UART) GigE interface only
11 Reserved
e
0 Each character received from the host is echoed back to it
1No Echo
Table 44: Baud rates: values
Note
This function is not available as GigE Vision feature.