Manual

Controlling image capture
GUPPY Technical Manual V7.1.0
172
The Guppy F-503 has two shutter modes:
electronic rolling shutter (ERS) and
global reset release shutter (GRR)
Guppy F-503, Trigger_Mode_0, electronic rolling shutter
IntEna is high, when all pixels are integrated simultaneously.
IntEna starts with start of exposure of last row.
IntEna ends with end of exposure of first row.
No IntEna if exposure of first row ends before the last row starts.
Long exposure time:
To get an IntEna signal the following condition must be true:
T
exp eff.
= T
exp
- T
frame
> 0
Note
With this two shutter modes only Trigger_Mode_0 is possible.
Details are explained in the following diagrams.
Figure 98: Trigger_Mode_0: Guppy F-503 electronic rolling shutter (long exposure time)
IntEna
T
row
FVal
T
exp
T
frame
Overlapping:
good for flash
T
exp
– T
frame
> 0