The entry with key D4 in the unit directory (440h in this case) provides the
offset for unit dependent info:
440h + 000001 * 4 = 444h
And finally, the entry with key 40 (448h in this case) provides the offset for
the camera control register:
FFFF F0000000h + 3C0000h * 4 = FFFF F0F00000h
The base address of the camera control register is thus:
FFFF F0F00000h
The offset entered in the table always refers to the base address of
F0F00000h.
Offset 0-7 8-15 16-23 24-31
434h 00 03 CRC
Unit directory 438h 12 00 A0 2D
43Ch 13 00 01 02
440h D4
00 00 01
Table 96: Config ROM
Offset 0-7 8-15 16-23 24-31
444h 00 0B
CRC
Unit dependent info 448h 40
3C 00 00
44Ch 81 00 00 0A
450h 82 00 00 0E
454h 38 00 00 00
458h 39 00 00 00
45Ch 3A 00 00 00
460h 3B 00 00 00
464h 3C 00 00 00
468h 3D 00 00 00
46Ch 3E 00 00 00
470h 3F 00 00 00
Table 97: Config ROM