User Manual

Controlling image capture
Guppy PRO Technical Manual V4.0.0
155
Example: Guppy PRO F-031
register value x time base + exposure time offset = exposure time
100 x 20 µs + 71 µs = 2075 µs exposure time
The minimum adjustable exposure time set by register is 4 µs. The real
minimum exposure time of Guppy PRO F-031 is then:
4 µs + 71 µs = 75 µs
Extended shutter
The exposure time for long-term integration of
up to 67 seconds for the CCD models
up to 22 seconds for the Guppy PRO F-503 (CMOS model)
can be extended via the advanced register: EXTENDED_SHUTTER
The longest exposure time, 3FFFFFFh, corresponds to 67.11 sec.
The lowest possible value of ExpTime is camera-specific (see Table 62: Cam-
era-specific minimum exposure time on page 154).
Camera Register value Time base (default)
Guppy PRO F-031 100 20 µs
Table 63: Register value and time base for Guppy PRO F-031
Register Name Field Bit Description
0xF100020C EXTD_SHUTTER Presence_Inq [0] Indicates presence of this feature (read
only)
--- [1.. 5] Reserved
ExpTime [6..31] Exposure time in µs
Table 64: Advanced register: Extended shutter
Note
Exposure times entered via the 81Ch register are mir-
rored in the extended register, but not vice versa.
Longer integration times not only increase sensitivity,
but may also increase some unwanted effects such as
noise and pixel-to-pixel non-uniformity. Depending on
the application, these effects may limit the longest
usable integration time.
Changes in this register have immediate effect, even
when the camera is transmitting.
Extended shutter becomes inactive after writing to a
format/mode/frame rate register.