Instruction manual
Guppy Technical ManualV7.4.0
227
Configuration of the camera
040h PACKET_PARA_INQ See note
044h BYTE_PER_PACKET Acc. to IIDC V1.3
Note
• For all modes in Format_7, ErrorFlag_1 and ErrorFlag_2
are refreshed on each access to the Format_7 Register.
• Contrary to IIDC V1.3, registers relevant to Format_7 are
refreshed on each access. The Setting_1 bit is automati-
cally cleared after each access.
• When ErrorFlag_1 or ErrorFlag_2 are set and Format_7 is
configured, no image capture is started.
• Contrary to IIDC V1.3, COLOR_CODING_ID is set to a
default value after an INITIALIZE or reset.
• Contrary to IIDC V1.3, the UnitBytePerPacket field is
already filled in with a fixed value in the PACK-
ET_PARA_INQ register.
Offset Name Notes
Table 102: Format_7 control and status register