Instruction manual
Guppy Technical ManualV7.4.0
39
Specifications
Spectral sensitivity
Power requirements DC 8 V - 36 V via IEEE 1394 cable or 8-pin HIROSE
Power consumption Less than 2 watt (@ 12 V DC)
Dimensions 48.2 mm x 30 mm x 30 mm (L x W x H); w/o tripod and lens
Mass 50 g (without lens)
Operating temperature + 5 °C ... + 45 °C housing temperature (without condensation)
Storage temperature - 10 °C ... + 70 °C ambient temperature (without condensation)
Regulations FCC Class B, CE, RoHS (2011/65/EU)
Standard accessories • b/w: C/CS-Mount with built-in protection glass
• color: C/CS-Mount with built-in IR cut filter
Optional accessories • b/w: C/CS-Mount: IR cut filter / IR pass filter available as CS-Mount adapter
• color: C/CS-Mount: protection glass available as CS-Mount adapter
Software packages http://www.alliedvision.com/en/support/software-downloads (free of charge)
Note
All measurements were done without protection glass /
without filter.
The uncertainty in measurement of the QE values is 10%.
This is mainly due to:
• Manufacturing tolerance of the sensor
• Uncertainties in the measuring apparatus itself
Feature Specification
Table 12: Specification Guppy F-503B/C