Instruction manual

Guppy Technical ManualV7.4.0
66
Camera interfaces
Outputs
Output features are configured by software. Any signal can be placed on any out-
put.
The main features of output signals are described below:
Note
This feature works with external Trigger_Mode_0 only.
Note
For a general description of the outputs and warnings see the
1394 Installation Manual.
Signal Description
IntEna (Integration Enable) signal This signal displays the time in which exposure was
made. By using a register this output can be
delayed up to 1.05 seconds.
Fval (Frame valid) signal This feature signals readout from the sensor. This
signal Fval follows IntEna.
Busy signal This signal appears when:
the exposure is being made or
the sensor is being read out or
data transmission is active.
The camera is busy.
Table 23: Output signals