Instruction manual

Guppy PRO Technical ManualV4.1.0
123
Controlling image capture
Short exposure time:
If the following condition is true:
T
exp eff.
= T
exp
- T
frame
< 0
you don’t get an IntEna signal and triggering is not possible.
Guppy PRO F-503, Trigger_Mode_0, global reset release
shutter
IntEna is high, when all pixels are integrated simultaneously.
Readout starts with end of exposure of first row.
Readout ends with (end of exposure of last row) + (1x T
row
).
Figure 65: Trigger_Mode_0: Guppy PRO F-503 electronic rolling shutter (short exposure time)
Note
For activating global reset release shutter in an advanced reg-
ister see table 153.
Figure 66: Trigger_Mode_0: Guppy PRO F-503: global reset release shutter
IntEna
T
exp
T
frame
No overlapping,
no IntEna,
no flash
T
exp
– T
frame
< 0
FVal
IntEna
FVal
T
row
T
exp
Overlapping
good for
flash
T
exp