Instruction manual

Guppy PRO Technical ManualV4.1.0
130
Controlling image capture
Debounce time
This register controls the debounce feature of the cameras input pins. The
debounce time can be set for each available input separately.
Increment is 500 ns
Debounce time is set in Time x 500 ns
Minimum debounce time is 1.5 μs 3 x 500 ns
Maximum debounce time is ~16 ms (2
15
-1) x 500 ns
Offset Name Field Bit Description
0xF1000840 IO_INP_DEBOUNCE_1 Presence_Inq [0] Indicates presence of this feature
(read only)
--- [2..7] Reserved
Time [8..31] Debounce time in steps of 500 ns
(24 bit) see examples above
0xF1000844 MinValue [0..31] Minimum debounce time
0xF1000848 MaxValue [0..31] Maximum debounce time
0xF100084C --- [0..31] Reserved
0xF1000850 IO_INP_DEBOUNCE_2 same as IO_INP_DEBOUNCE_1
0xF1000860 IO_INP_DEBOUNCE_3 same as IO_INP_DEBOUNCE_1
0xF1000870 IO_INP_DEBOUNCE_4 same as IO_INP_DEBOUNCE_1
0xF1000880 Reserved
0xF1000890 Reserved
0xF10008A0 Reserved
0xF10008B0 Reserved
Table 64: Advanced register: Debounce time for input ports
Note
The camera corrects invalid values automatically.
This feature is not stored in the user settings.