Instruction manual
Guppy PRO Technical ManualV4.1.0
135
Controlling image capture
One-shot command on the bus to start of 
exposure
The following sections describe the time response of the camera using a single 
frame (one-shot) command. As set out in the IIDC specification, this is a soft-
ware command that causes the camera to record and transmit a single frame.
The following values apply only when the camera is idle and ready for use. Full 
resolution must also be set.
Microcontroller sync is an internal signal. It is generated by the microcontroller 
to initiate a trigger. This can either be a direct trigger or a release for ExSync if 
the camera is externally triggered.
Feature Value
One-shot  microcontroller sync 150 μs (processing time in the 
microcontroller)
μC-Sync/ExSync  integration start 8 μs
 Table 70: Values for one-shot