Configuration of the camera
Extended shutter
The exposure time for long-term integration of up to 67 seconds can be entered
with μs precision via the EXTENDED_SHUTTER register.
The minimum allowed exposure time depends on the camera model. To deter-
mine this value write 1 to the ExpTime field and read back the minimum allowed
exposure time.
The longest exposure time, 3FFFFFFh, corresponds to 67.11 seconds.
Test images
Bit [8] to [14] indicate which test images are saved. Setting bit [28] to [31] acti-
vates or deactivates existing test images.
By activating any test image the following auto features are automatically dis-
abled:
auto gain
auto shutter
auto white balance
Note
The ABSOLUTE VALUE CSR register, introduced in IIDC V1.3, is
not implemented.
Register Name Field Bit Description
0xF100020C EXTD_SHUTTER Presence_Inq [0] Indicates presence of this fea-
ture (read only)
--- [1..5] Reserved
ExpTime [6..31] Exposure time in μs
Table 133: Advanced register: Extended shutter
Note
Exposure times entered via the 81Ch register are mirrored
in the extended register, but not vice versa.
Changes in this register have immediate effect, even
when camera is transmitting.
Extended shutter becomes inactive after writing to a for-
mat / mode / frame rate register.
Extended shutter setting will be overwritten by the nor-
mal time base/shutter setting after Stop/Start of FireV-
iew or FireDemo.