Instruction manual
Guppy PRO Technical ManualV4.1.0
98
Description of the data path
Activate/deactivate defect pixel correction
Activate:
1. Set ON_OFF flag to 1.
Deactivate:
1. Set ON_OFF flag to 0.
Store defect pixel data non-volatile
1. Set the MemSave flag to 1.
Load non-volatile stored defect pixel data
1. Set the MemLoad flag to 1.
All non-volatile stored defect pixel coordinates are loaded.
Send defect pixel data to the host
1. Set EnaMemRD flag to 1.
Defect pixel data is transferred from dual port RAM to host.
2. Read DPDataSize.
This is the current defect pixel count from the camera.
Receive defect pixel data from the host
1. Set EnaMemWR flag to 1.
Binning (only b/w cameras; F-503: also color
cameras)
2 x binning (F-503 also 4 x)
Definition Binning is the process of combining neighboring pixels while being read out
from the sensor.
Note
• Switch off camera and switch on again:
defect pixel data will get lost
• Initialize camera (start-up or soft reset):
non-volatile stored defect pixel data are loaded auto-
matically