Filter and lenses
The following tables list selected image formats in width x height depending
on camera type, distance and the focal length of the lens.
Note
Lenses with focal lengths < 8 mm may show shading in the
edges of the image due to microlenses on the sensor's pixel.
Ask your dealer if you require non C-Mount lenses.
Focal length for type 1/4 sensors: Manta G-031 Distance = 500 mm Distance = 1000 mm
2.8 mm 655 mm x 490 mm 1314 mm x 983 mm
4 mm 458 mm x 342 mm 919 mm x 687 mm
6 mm 304 mm x 227 mm 611 mm x 457 mm
8 mm 227 mm x 170 mm 458 mm x 342 mm
12 mm 150 mm x 112 mm 304 mm x 227 mm
16 mm 112 mm x 83 mm 227 mm x 170 mm
25 mm 70 mm x 52 mm 114 mm x 108 mm
Table 20: Focal length vs. field of view (Manta G-031)
Focal length for type 1/3 sensor: Manta G-032 Distance = 500 mm Distance = 1000 mm
4.0 mm 608 mm x 446 mm 1220 mm x 896 mm
4.8 mm 506 mm x 371 mm 1016 mm x 746 mm
8 mm 301 mm x 221 mm 608 mm x 446 mm
12 mm 199 mm x 146 mm 403 mm x 296 mm
16 mm 148 mm x 109 mm 301 mm x 221 mm
25 mm 93 mm x 68 mm 191 mm x 140 mm
35 mm 65 mm x 48 mm 135 mm x 99 mm
Table 21: Focal length vs. field of view (Manta G-032)
Focal length for type 1/3 sensors: Manta G-095/125 Distance = 500 mm Distance = 1000 mm
4.0 mm 595 mm x 446 mm 1195 mm x 896 mm
4.8 mm 495 mm x 371 mm 995 mm x 746 mm
8 mm 295 mm x 221 mm 595 mm x 446 mm
12 mm 195 mm x 146 mm 395 mm x 296 mm
16 mm 145 mm x 109 mm 295 mm x 221 mm
25 mm 91 mm x 68 mm 187 mm x 140 mm
35 mm 64 mm x 48 mm 132 mm x 99 mm
Table 22: Focal length vs. field of view (Manta G-095/125)