Sequence control
It is possible to make certain settings for a sequence of images beforehand
by using this register.
Register Name Field Bit Description
0xF1000220 SEQUENCE_CTRL Presence_Inq [0] Indicates presence of this
feature (read only)
--- [1..4] Reserved
AutoRewind [5]
ON_OFF [6] Enable/Disable this feature
--- [7..15] Reserved
MaxLength [16..23] Maximum possible length of a
sequence (read only)
SeqLength [24..31] Length of the sequence
0xF1000224 SEQUENCE_PARAM --- [0..4] Reserved
ApplyParameters [5] Apply settings to selected
image of sequence; auto-reset
IncImageNo [6] Increment ImageNo after
ApplyParameters has finished
--- [7..23] Reserved
ImageNo [24..31] Number of image within a
sequence
Table 106: Sequence control register